Datapoints for p + se76 -> n + br76

Back to rate

Calculate Rate at a
Specific Temperature

T9: GK
Results: 0 cm3 mol-1 s-1

Data Points for
Standard Temperatures

Temperature Value
0.1 2.997911e-281
0.15 9.719920e-185
0.2 1.745948e-136
0.3 3.126061e-88
0.4 4.173743e-64
0.5 1.245379e-49
0.6 5.556400e-40
0.7 4.335294e-33
0.8 6.396826e-28
0.9 6.699732e-24
1 1.101402e-20
1.5 4.868637e-11
2 3.209550e-06
2.5 2.475884e-03
3 2.061124e-01
3.5 4.798053e+00
4 5.027742e+01
4.5 3.089639e+02
5 1.305000e+03
6 1.095052e+04
7 4.784364e+04
8 1.381595e+05
9 3.011262e+05
10 5.365186e+05