Datapoints for p + kr85 -> n + rb85
Back to rateCalculate Rate at a
Specific Temperature
Data Points for
Standard Temperatures
| Temperature | Value |
|---|---|
| 0.1 | 1.325894e-18 |
| 0.15 | 1.959531e-15 |
| 0.2 | 2.013494e-13 |
| 0.3 | 8.836994e-11 |
| 0.4 | 5.510758e-09 |
| 0.5 | 1.276432e-07 |
| 0.6 | 1.611899e-06 |
| 0.7 | 1.346257e-05 |
| 0.8 | 8.315015e-05 |
| 0.9 | 4.076450e-04 |
| 1 | 1.664165e-03 |
| 1.5 | 3.085738e-01 |
| 2 | 9.554550e+00 |
| 2.5 | 1.092777e+02 |
| 3 | 6.668711e+02 |
| 3.5 | 2.660944e+03 |
| 4 | 7.867742e+03 |
| 4.5 | 1.872591e+04 |
| 5 | 3.800968e+04 |
| 6 | 1.136619e+05 |
| 7 | 2.640727e+05 |
| 8 | 5.473150e+05 |
| 9 | 1.107139e+06 |
| 10 | 2.324246e+06 |
| View Graph | |
This material is based upon work supported in part by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Award Number DE-SC0026204.