Datapoints for n + cs136 -> p + xe136
Back to rate
Calculate Rate at a
Specific Temperature
Data Points for
Standard Temperatures
| Temperature |
Value |
| 0.1 |
2.033701e-09 |
| 0.15 |
5.587171e-09 |
| 0.2 |
1.432052e-08 |
| 0.3 |
7.967175e-08 |
| 0.4 |
3.694481e-07 |
| 0.5 |
1.475501e-06 |
| 0.6 |
5.199417e-06 |
| 0.7 |
1.646908e-05 |
| 0.8 |
4.758141e-05 |
| 0.9 |
1.268685e-04 |
| 1 |
3.151916e-04 |
| 1.5 |
1.310161e-02 |
| 2 |
2.062051e-01 |
| 2.5 |
1.708258e+00 |
| 3 |
9.015729e+00 |
| 3.5 |
3.424774e+01 |
| 4 |
1.017749e+02 |
| 4.5 |
2.511714e+02 |
| 5 |
5.381576e+02 |
| 6 |
1.838465e+03 |
| 7 |
4.930349e+03 |
| 8 |
1.178755e+04 |
| 9 |
2.742389e+04 |
| 10 |
6.610342e+04 |
|
View Graph
|