Datapoints for n + ru99 -> ru100
Back to rateCalculate Rate at a
Specific Temperature
Data Points for
Standard Temperatures
| Temperature | Value |
|---|---|
| 0.1 | 8.169232e+07 |
| 0.15 | 8.798114e+07 |
| 0.2 | 9.089352e+07 |
| 0.3 | 9.152377e+07 |
| 0.4 | 8.913273e+07 |
| 0.5 | 8.575033e+07 |
| 0.6 | 8.217486e+07 |
| 0.7 | 7.872792e+07 |
| 0.8 | 7.553166e+07 |
| 0.9 | 7.262102e+07 |
| 1 | 6.999256e+07 |
| 1.5 | 6.027771e+07 |
| 2 | 5.421807e+07 |
| 2.5 | 4.995375e+07 |
| 3 | 4.648054e+07 |
| 3.5 | 4.324770e+07 |
| 4 | 3.995841e+07 |
| 4.5 | 3.647617e+07 |
| 5 | 3.277484e+07 |
| 6 | 2.496809e+07 |
| 7 | 1.739297e+07 |
| 8 | 1.097499e+07 |
| 9 | 6.236337e+06 |
| 10 | 3.179531e+06 |
| View Graph | |
This material is based upon work supported in part by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Award Number DE-SC0026204.