Datapoints for he4 + au172 -> p + hg175
Back to rate
Calculate Rate at a
Specific Temperature
Data Points for
Standard Temperatures
| Temperature |
Value |
| 0.1 |
0.000000e+00 |
| 0.15 |
1.777920e-298 |
| 0.2 |
4.536977e-217 |
| 0.3 |
1.834731e-139 |
| 0.4 |
9.176708e-104 |
| 0.5 |
5.959759e-84 |
| 0.6 |
1.543302e-71 |
| 0.7 |
4.890176e-63 |
| 0.8 |
8.505784e-57 |
| 0.9 |
5.923370e-52 |
| 1 |
5.038795e-48 |
| 1.5 |
5.280483e-35 |
| 2 |
9.680989e-27 |
| 2.5 |
1.022103e-20 |
| 3 |
3.310447e-16 |
| 3.5 |
7.582048e-13 |
| 4 |
2.192536e-10 |
| 4.5 |
1.272555e-08 |
| 5 |
2.191100e-07 |
| 6 |
6.223532e-06 |
| 7 |
4.530052e-05 |
| 8 |
4.567632e-04 |
| 9 |
2.373866e-02 |
| 10 |
1.792850e+01 |
|
View Graph
|