Datapoints for lu154 -> he4 + tm150
Back to rateCalculate Rate at a
Specific Temperature
Data Points for
Standard Temperatures
| Temperature | Value |
|---|---|
| 0.1 | 4.257763e-211 |
| 0.15 | 2.734079e-137 |
| 0.2 | 9.115751e-98 |
| 0.3 | 1.989541e-57 |
| 0.4 | 8.849233e-38 |
| 0.5 | 1.289994e-26 |
| 0.6 | 1.237426e-19 |
| 0.7 | 5.850074e-15 |
| 0.8 | 1.165661e-11 |
| 0.9 | 3.151250e-09 |
| 1 | 2.283691e-07 |
| 1.5 | 4.086790e-02 |
| 2 | 2.193251e+01 |
| 2.5 | 1.774162e+03 |
| 3 | 5.523143e+04 |
| 3.5 | 8.968161e+05 |
| 4 | 8.696370e+06 |
| 4.5 | 5.475741e+07 |
| 5 | 2.390534e+08 |
| 6 | 1.903782e+09 |
| 7 | 6.621160e+09 |
| 8 | 1.433260e+10 |
| 9 | 2.618632e+10 |
| 10 | 5.237763e+10 |
| View Graph | |
This material is based upon work supported in part by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Award Number DE-SC0026204.