Datapoints for he4 + he4 + he4 -> c12

Back to rate

Calculate Rate at a
Specific Temperature

T9: GK
Results: 0 cm3 mol-1 s-1

Data Points for
Standard Temperatures

Temperature Value
0.1 2.040319e-24
0.15 1.431146e-18
0.2 9.446610e-16
0.3 4.383800e-13
0.4 7.281859e-12
0.5 3.365538e-11
0.6 8.428240e-11
0.7 1.510177e-10
0.8 2.216188e-10
0.9 2.865001e-10
1 3.404107e-10
1.5 4.391063e-10
2 3.890147e-10
2.5 3.118405e-10
3 2.435810e-10
3.5 1.900532e-10
4 1.494957e-10
4.5 1.189630e-10
5 9.588013e-11
6 6.473061e-11
7 4.590711e-11
8 3.408715e-11
9 2.641956e-11
10 2.132083e-11
View Graph

Comparison with Literature Sources

T9 Literature Calculated Difference
0.01 6.30957E-71 6.04252764666E-71 4.2323 %
0.1 2.0417E-24 2.04031924128E-24 0.0676 %
1 3.46E-10 3.40410661233E-10 1.6154 %
10 2.089296E-11 2.1320831532E-11 2.0479 %