Datapoints for cl61 -> n + cl60

Back to rate

Calculate Rate at a
Specific Temperature

T9: GK
Results: 0 cm3 mol-1 s-1

Data Points for
Standard Temperatures

Temperature Value
0.1 9.981157e-61
0.15 5.959275e-37
0.2 4.685838e-25
0.3 3.704832e-13
0.4 3.289843e-07
0.5 1.222221e-03
0.6 2.951781e-01
0.7 1.501812e+01
0.8 2.896724e+02
0.9 2.934552e+03
1 1.898089e+04
1.5 6.144014e+06
2 1.439513e+08
2.5 1.200141e+09
3 5.952398e+09
3.5 2.170634e+10
4 6.440560e+10
4.5 1.640590e+11
5 3.699107e+11
6 1.394654e+12
7 3.745338e+12
8 7.433249e+12
9 1.111046e+13
10 1.264343e+13
View Graph

Comparison with Literature Sources

T9 Literature Calculated Difference