Datapoints for n + ni78 -> ni79
Back to rateCalculate Rate at a
Specific Temperature
Data Points for
Standard Temperatures
| Temperature | Value |
|---|---|
| 0.1 | 5.229040e+01 |
| 0.15 | 4.580772e+01 |
| 0.2 | 4.256852e+01 |
| 0.3 | 3.917560e+01 |
| 0.4 | 3.732209e+01 |
| 0.5 | 3.616328e+01 |
| 0.6 | 3.543615e+01 |
| 0.7 | 3.502631e+01 |
| 0.8 | 3.487188e+01 |
| 0.9 | 3.493449e+01 |
| 1 | 3.518836e+01 |
| 1.5 | 3.884917e+01 |
| 2 | 4.603230e+01 |
| 2.5 | 5.677824e+01 |
| 3 | 7.150458e+01 |
| 3.5 | 9.074946e+01 |
| 4 | 1.150029e+02 |
| 4.5 | 1.445463e+02 |
| 5 | 1.792880e+02 |
| 6 | 2.612510e+02 |
| 7 | 3.481457e+02 |
| 8 | 4.184883e+02 |
| 9 | 4.497007e+02 |
| 10 | 4.294246e+02 |
| View Graph | |